• Image 1
  • Image 2

TPI 716A740 Flue Gas Analyzer with Infrared Printer

Our Price: $1,284.37

    Product Description

    The TPI Model 716 Flue Gas Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion.

    • Built-in differential manometer with 0.001” H2O resolution
    • Calculates combustion efficiency
    • Data Logging with time and date stamp
    • Will not shut off if 15 ppm CO is present for increased safety
    • Communicate to a PC via the USB interface
    • Optional A740 IR printer available for hard copies of test results
    • Built-in differential thermometer
    • Push on fittings for fast and easy use
    • New! Optional Bluetooth interface

    Quick and Simple Setup

    All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selectionduring start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need toperform fuel selection every time the analyzer is turned on.
    The TPI 716 Flue Gas Analyzer comes complete with the following standard accessories: 
    ( ) Denotes part number

    • TPI 716 Analyzer
    • Combustible Gase Leak Probe (A806)
    • Rubber Boot (A765) 1 each installed on analyzer
    • Soft Carrying Case (A768) – 1 each
    • Flue Sampling Probe (A770) – 1 each
    • In-Line Filter / Water Trap installed on Flue probe (A796) – 1 each
    • Disc water filter installed in water trap (A794W) – 1 each
    • Temperature Probe (GK11M) – 1 each
    • Battery Charger (A766) – 1 each
    • Mini Pump Protection Filter Assembly (A763) – 1 each
    • Exhaust Spigot Removable (A764) – 1 each
    • Pressure Tubing (A774) – 1 each 6’ piece
    • Static Pressure Tips (A776) – 2 each
    • 1/4” barbed to 1/8” NPT fitting (A603) – 2 each
    • Gas Valve Adapter (A611) – 1 each
    • Instruction Manual
    • A740 infrared printer
     Model 716 Specifications
     Operating Temperature Range  14°F to +122°F (-10°C to +50°C)
     Battery / Batery Life  Rechargeable Ni-MH / > 6 Hours
     Charger Input Voltage  115V or 230V : 50/60 Hz AC
     Fuels  Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
     Anthracite Coal, Coke, Butane, Wood, Bagasse
     Pressure Ranges  mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
     Display  Backlit Graphic LCD
     Data Storage  100 sets of readings, multiple pages
     Time and Date  24 Hour Real Time Clock
     Dimensions  7.8” (200mm) x 3.5” (90mm) x 2.4” (60mm)
     Weight  1.1lbs (500g)
     Conforms to  EN50379


     Flue Temperature Probe
     Construction  Pistol Grip with Stainless Steel Shaft
     Hose Length  8.2’ (2500mm)
     Insertion Length  7.9” (200mm)
     'K' Type Thermocouple Accuracy  +/- 0.3% of fullscale, +/- 2°F (1°C)
     Maximum Temperature  1472°F (800°C)


     Gases  Range  Resolution  Accuracy
     Oxygen  0-25%  0.1%  +/- 0.3%
     Carbon Monoxide (low)  0-10,000 ppm  1 ppm  (<100ppm) +/- 5 ppm
     (>=100ppm) +/- 5%
     Carbon Monoxide (high)  0-100,000 ppm  0.001%  >10,000ppm: +/- 10%
     Nitric Oxide *  0-5000ppm  1 ppm  +/- 5ppm (<100ppm)
     +/- 5% (<1000ppm)
     +/- 10% (>1000ppm)
     Carbon Dioxide  0-25%  0.1%  Calculated
     CO/CO2 Ratio  0-0.999  0.001  Calculated
     Combustion Efficiency  0-100%  0.1%  Calculated
     Gas Leak Sensor  100-10,000ppm (calibrated to methane)

    * if fitted 

     Pressure Measurement
     Selectable Ranges  mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
     Range  - 100 mbar to + 100 mbar
     -10 kPa to + 10 kPa
     -40 inH2O to 40 inH2O
     Resolution  0.001 mbar (0~9.999 mbar)
     0.01 mbar (10.00~99.99 mbar)
     Accuracy  < 5 mbar: +/- 0.05 mbar
     > 5 mbar: +/- 1% of reading


     Temperature Measurement
     Input Type  K-Type thermocouple
     Range  -58°F to 2372°F (-50°C to 1300°C)*
     Resolution  1°F (1°C)
     Accuracy  +/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C)


    TPI Model A740 Infrared Printer. Use the A740 with select TPI instruments to print hard paper copies of your measurement data.

    • Power On indication (red LED)
    • Adjustable contrast (low, norm, high)
    • Manual paper feed (advance)
    • Operates on 4 “AA” batteries or optional AC adapter
    • Self test at Power On
    • 18 inch maximum transmitting distance
    • Thermal paper
    • Back side magnet

    A740 Infrared Printer Operating Instructions

    1. Make sure the paper is loaded.
    2. Turn the A740 printer on.
    3. Hold the test equipment within 18 inches at the recommended angles.
    4. Activate the print function on the test equipment. A740 will start to print automatically. Do not obstruct IR beam during printing process.
    5. Adjust print contrast as desired.


     Model A740 Specifications
     Maximum Transmitting Distance  18 inches (45cm)
     Maximum Horizontal Receiving Angle  ±30°
     Vertical Receiving Angle  -10° to + 20°
     Battery Power  4 x 1.5V Alkaline battery
     Adapter  DC 7V / 1500mA, 50Hz, 240V (CE)
     DC 9V / 1A, 60Hz, 120V (CUL)
     Paper  A746
     Operating Temperature  32° to 122°F (0° to 50°C)
     Operating Humidity  5% to 80% RH
     Storage Temperature  14° to 140°F (-10° to 60°C)

    Product Reviews