TPI 775 Combination Carbon Monoxide & Combustion Gas Leak Detector

Retail:
Our Price: $354.33
    SKU:
    TPI-775
    Quantity:

    Product Description

    The combo CO/Combustible gas detector is the first of its kind to combine both detection technologies into one easy to use hand-held and affordable instrument.

    The TPI 775 is a state-of-the-art Carbon Monoxide and Combustible Gas Leak Detector. It is the first of its kind to combine both detection technologies into one easy to use hand-held affordable instrument.

    • One hand operation
    • Auto Zero
    • Backlight
    • Visable and audible alarm
     Model 775 Specifications
     Carbon Monoxide (CO) Measurement  Range 0 ~ 2,000ppm
     Accuracy  ±5ppm or 5% of reading whichever is greater
     Resolution  1ppm
     Data Storage  No
     IR Printer Port  No
     Flue Probe  No
     Internal Pump  No
     Combustible Gas Leak Detection  Yes
     Backlight  Yes
     Alarm  Audible + Visual
     Power Supply  1.5V AA (2)
     Dimensions  9.5” x 2.9” x 2.2” (240 x 74 x 55 mm)
     Weight  1.05lbs (476g)

    Don’t expose yourself to Carbon Monoxide!

    Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

    • 9ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
    • 50ppm: The Federal OSHA standard for continuous exposure in any eight hour period.
    • 200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours.
    • 400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA.
    • 800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes.
    • 1600ppm*: Headache, dizziness, and nausea within 20 minutes. Death within 1 hour.
    • 3200ppm*: Headache, dizziness, and nausea within 5-10 minutes. Death within 30 minutes.
    • 6400ppm*: Headache, dizziness, and nausea within 1-2 minutes. Death within 10-15 minutes.
    • 12800ppm*: Death within 1-3 minutes.

    * With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.